Installation
GECON Lite is supplied as a board with four holes for mounting. You can mount the Gecon by attached special
stickers or screws (screws are not included in the package). If you are placing the Gecon inside of metal box, use
an external antenna and place it outside the box. External antenna is also recommended in locations with lower
signal level.
Warning !!!
You have to disable PIN on the SIM card and delete all SMS messages before placing it into the
communicator.
Disabling PIN code
Put the SIM card into a standard mobile phone and turn the phone on. Insert the PIN code during phone
startup. Navigate through the phone menu to security settings and disable PIN code protection. Now the SIM card
is ready for configuaration in the Gecon communicator. Turn off the phone, remove the SIM card.
GECON Lite Startup
•
Insert the SIM into the Gecon Lite (be sure PIN code is disabled)
•
Connect the Gecon to voltage.
•
Registration to GSM network. If the Gecon is not registered within 60 seconds (see LED status
signalization section below), please check the SIM card and signal strength.
•
Gecon is ready for use.
LED status signalization:
•
Slow LED blinking (on/off in 1:1 seconds) – GSM network unavailable.
•
Short LED blinking (one blink every 4 seconds) – registered into GSM network
•
Permanent shine– event detected on the input (alarm/trouble), device is sending SMS and calls according
to the settings.
If the shines only for few seconds (2.5 seconds) the numbers for the input are not set correctly.
Gecon Lite Plus Setup
GECON LITE PLUS is GSM gateway that allows several modes of operation, therefore it is necessary to
setup parameters according to customer needs.
1. Phone numbers
2. Input logic NO/NC
3. Type of input ALARM/TROUBLE
4. Additional functions
For convenient setup, settings of Gecon are set by SMS commands from mobile phone. For security reasons,
each SMS has to begin with password. Default password is abcd, it is recommended to change the password
immediately. Gecon is not case sensitive, you can use both small and capital letters.
Current settings:
You can view the current settings by sending following query SMS to GECON phone number. Gecon will reply you
with SMS containing current settings
VER
- device version
PHONE
- phone numbers settings
TEXT
- texts settings
SETUP
- other parameters settings
WPRINT
- dictionary for online print (reply by TWO SMS messages)
HELP
- lists all query SMS options
?
- current status of inputs and relays
Example:
abcd SETUP
Note:
While setup SMS message can contain several commands, query SMS above can contain only one
commad in one query SMS.