Gardsman CTC-1132 Installation, Programming, Operating - page 23
19
)
A for Home Access Door Contact
z
When the system is in Away arm
mode, if Home Access Door Contact
is triggered, a burglar alarm will be
activated immediately.
z
When the system is in Home arm
mode, if a Home Access Door
Contact is triggered, the Control Panel
will start an Entry Delay period to give
enough time to disarm the system.
z
During the Entry Delay or Exit Delay
period, if a Home Access Door
Contact is triggered, the Control Panel
will not respond.
)
D for Delay Door Contact
z
When the system is in Away arm /
Home arm mode, if a Delay Door
Contact is triggered, a burglar alarm
will be activated immediately.
z
During the Entry Delay or Exit Delay
period, if a Delay Zone Door Contact
is triggered, the Control Panel will not
respond.
)
E for Entry Door Contact
z
When the system is in Away arm /
Home arm mode, if an Entry Door
Contact is triggered, the Control Panel
will start an entry period to give
enough time to disarm the system.
z
After the delay period is expired and
no correct PIN code is entered to
disarm the system, the Control Panel
will respond with a Burglar Alarm
after 30 secs.
z
When the system is in Alarm off mode,
if an Entry Door Contact is triggered,
the Control Panel will make a ding-
dong sound for Door Chime (if
programmed). To program Door
Chime, please refer to section Door
Chime.
)
P for Away Entry Door Contact
z
When the system is in Away arm
mode, if an Away Entry Door Contact
is triggered, the Control Panel will
start an entry period to give enough
time to disarm the system.
z
After the delay period is expired and
no correct PIN code is entered to
disarm the system, the Control Panel
will respond with a Burglar Alarm
after 30 secs.
z
When the system is in Alarm off mode,
if an Away Entry Door Contact is
triggered, the Control Panel will make
a ding-dong sound for Door Chime (if
programmed).
z
When the system is in Home arm
mode, if an Away Entry Door Contact
is triggered, the Control Panel will not
respond.
z
During the Entry Delay or Exit Delay
period, if an Away Entry Door Contact
is triggered, the Control Panel will not
respond.
)
H for 24 Hour Door Contact
z
The 24 Hour Door Contact is active all
the time and does not have to be
armed or disarmed.
)
F for Fire Door Contact
z
The Fire Door Contact is active all the
time and does not have to be armed
or disarmed.
)
M for Medical Emgenercy Door
Contact
z
A Medical Emg Door Contact is
active all the time and does not have
to be armed or disarmed.
)
W for Water Door Contact
z
Water Door Contact acts as an
Universal Transmitter and have a
Water leakage sensor connected to it.
z
The Water Door Contact is active all
the time and does not have to be
armed or disarmed.
StepA8.Use the S&T to make your selection
and confirm by pressing OK key. You
are now invited to give a name or
location description to the device to
help understand system events. You
can enter up to 10 letters as you want
for the name followed by OK key or
just press OK key for no name.
Please see section Device Naming
for details.