Jacuzzi J - 355 Owner's Manual - J-300 Series
J-300 Series
Export J-335, J-345, J-355, J-365 & J-375 Models (50Hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A
30A
40A
Number of Wires:
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
15A
23A
29A
*
In 20A configuration, the heater
will not operate
while either jets pump
is running in high speed.
This is the factory setting.
Note: pump 2 runs
only in high speed.
**
In 30A configuration, the heater
will operate
while one jets pump is
running in high speed.
Note: pump 2 runs only in high speed.
***
In 40A configuration the heater
will operate
while both jets pumps are
running in high speed.
Export J-315 & J-325 Models (50Hz)
230V/20A*
230V/30A**
Circuit Breaker:
20A†
30A†
Number of Wires:
3
3
Frequency:
50Hz
50Hz
Current Draw:
15A
21A
*
In 20A configuration, the heater
will not operate
while the jets pump is
running in high speed.
This is the factory setting.
**
In 30A configuration, the heater
will operate
while one jets pump is
running in high speed.
11