11.3 Lock Modes (L1-L2)
These modes are designed for use during spa service or to prevent unauthorized
use.
11.4 Selecting The Filtration/Heating Mode
Press and hold both control panel WARMER (
) and COOLER (
) buttons at
the same time, then release. Then press either WARMER (
) or COOLER (
)
button to select filtration/heating mode F0-F6 or lock modes L1-L2 below:
Standard Filtration/Heating Modes
F0
5 minutes of filtration per day (one 5 minute “Blow-Out”
cycle every 24 hours to purge all plumbing lines)
F1
1 hour of filtration per day (one 30-minute cycle every 12
hours);
This is the factory default setting.
F2
1.5 hours of filtration per day (one 30-minute cycle every 8
hours)
F3
2 hours of filtration per day (one 30-minute cycle every 6
hours)
Economy Filtration/Heating Modes
F4
1 hour of filtration/heating per day (one 30-minute cycle
every twelve hours)
F5
1.5 hours of filtration/heating per day (one 30-minute cycle
every eight hours)
F6
2 hours of filtration/heating per day (one 30-minute cycle
every six hours)
Lock Modes
L1
Lock Out: disables all spa functions to permit filter
cleaning.
L2
Lock Mode: disables the jets and light buttons to prevent
unauthorized use of spa. Filtration/heating cycle will
continue to operate as programmed in this mode. The temperature display
flashes when this function is enabled.
EXAMPLE: the “F3” filtration/heating
cycle was enabled prior to choosing lock mode. The spa continues to perform the
“F3” cycle until lock mode is canceled, allowing another cycle to be selected.
To set a time for the first filtration/heating cycle, simply turn power on to the spa
two minutes prior to the desired time.
EXAMPLE: If you desire your first filtration/
heating cycle to begin at 10:00 AM turn off power to the spa and turn it back on again
at 9:58 AM. Note: start time is approximate and may vary slightly from day to day.