Jenn-Air JMD2124WS Technical Education - page 18
3-2
SENSOR COOKING CONDITION
Using the SENSOR function, food is cooked
without figuring time, power level or quantity.
When the oven senses enough steam from
the food, it relays the information to its micro-
processor which will calculate the remaining
cooking time and power level needed for
best results. When the food is cooked, water
vapor is developed. the sensor "senses" the
vapor and its resistance increase gradually.
When the resistance reaches the value set
according to the menu, supplementary cook-
ing is started. The time of supplementary
cooking is determined by experiment with
each food category and inputted into the LSI.
An example of how sensor works: (Potatoes)
1. Potatoes at room temperature. Vapor is
emitted very slowly.
switch, relay(RY1) and secondary inter-
lock relay (RY2), causing the fuse to blow.
POWER LEVEL P-0 TO P-90 COOKING
When Variable Cooking Power is pro-
grammed, the 120 volts A.C. is supplied to
the power transformer intermittently
through the contacts of relay (RY-2) which is
operated by the control unit within a 32 sec-
ond time base. Microwave power operation
is as follows:
VARI-MODE
ON TIME
OFF TIME
Power 10(P-HI) 32 sec.
0 sec.
(100% power)
Power 9(P-90) 30 sec.
2 sec.
(approx. 90% power)
Power 8(P-80) 26 sec.
6 sec.
(approx. 80% power)
Power 7(P-70) 24 sec.
8 sec.
(approx. 70% power)
Power 6(P-60) 22 sec.
10 sec.
(approx. 60% power)
Power 5(P-50) 18 sec.
14 sec.
(approx. 50% power)
Power 4(P-40) 16 sec.
16 sec.
(approx. 40% power)
Power 3(P-30) 12 sec.
20 sec.
(approx. 30% power)
Power 2(P-20) 8 sec.
24 sec.
(approx. 20% power)
Power 1(P-10) 6 sec.
26 sec.
(approx. 10% power)
Power 0(P-0)
0 sec.
32 sec.
(0% power)
2. Heat Potatoes. Moisture and humidity is
emitted very rapidly. You can smell the
aroma as it cooks.
3.Sensor detects moisture and humidity and
calculates cooking time and variable power.
Note: The ON/OFF time ratio does not
correspond with the percentage of
microwave power, because approxi-
mately . 2 seconds are needed for