Jenn-Air JMD2124WS Technical Education - Removing The Magnetron
4-15
REMOVING THE MAGNETRON
5. Remove the high voltage transfomer,
(see steps 1-7 on page 4-14). This step
is necessary to provide clearance for
magnetron removal.
6. Remove four connectors.
7. Remove one screw that secures the
magnetron to the magnetron air guide,
see figure 1.
8. Remove one screw that secures the
magnetron to the magnetron duct,
see figure 1.
9. Remove the four screws that secure the
magnetron to the microwave from the
top.
10. Drop the magnetron down and replace
or repair.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug microwave drawer or disconnect
power.
2. Remove the microwave drawer from the
cabinet as outlined in steps 1-4 of
Accessing Internal Components (see
page 4-2 for the procedure).
3. Remove the top, side and back panels
as outlined in the steps Accessing
Internal Components (see page 4-2 and
4-3 for the procedure).
4. Discharge the high voltage
capacitor terminals with a 20,000 W
2 watt resistor to chassis ground.
Figure 2
Four Screws
Screw
Air Guide
Screw
Magnetron
Duct
Four
Connectors