Jenn-Air JMD2124WS Technical Education - Warning
4-13
6. Remove the mounting screw from the
capacitor bracket and diode ring
terminal, see figure 2.
7. Disconnect the diode wire from the
magnetron terminal and remove the
diode.
8. Reassemble in reverse order.
5. Remove one screw and disengage the
capacitor mounting bracket from the tab
on the microwave base, see figure 1.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
REMOVING THE HIGH VOLTAGE CAPACITOR AND DIODE
1. Unplug microwave drawer or disconnect
power.
2. Remove the microwave drawer from the
cabinet as outlined in steps 1-4 of
Accessing Internal Components (see
page 4-2 for the procedure).
3. Remove the top, side and back panels
as outlined in the steps Accessing
Internal Components (see page 4-2 and
4-3 for the procedure).
4. Discharge the high voltage
capacitor terminals with a 20,000 W
2 watt resistor to chassis ground.
Figure 1
Screw
Tab
Red Wire To
Transformer
White Wire To
Transformer
Red Wire To
Magnetron
High Voltage Diode
Diode Screw
Figure 2