Jenn-Air JMD2124WS Technical Education - Removing The Stirrer Motor
Other manuals for JMD2124WS:
Use And Care Manual, Installation Instructions Manual
of
52
4-11
REMOVING THE STIRRER MOTOR
REMOVING THE HUMIDITY SENSOR
1. Unplug microwave drawer or disconnect
power.
2. Remove the microwave drawer from the
cabinet. (see page 4-2 for the
procedure).
3. Remove the top panel. (see page 4-2
figure 2.)
Humidity Sensor
Stirrer Motor
Figure 1
(left rear with the top panel removed)
Black Red and
White Shielded
Wires
CNF
Figure 2
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
4. Remove two screws securing the
humidity sensor to the microwave top,
see figure 1.
5. Disconnect the connector with the
shielded black red and white wires from
the control PCB at location CNF,
see figure 2.
Two Screws