Jenn-Air JMD2124WS Technical Education - Removing The Power Cord
4-4
4. Attach the black and white AC terminals
from the new Power Cord to the Noise
Filter as shown in figure 1.
Figure 2
REMOVING THE POWER CORD
Un-hook Ground to metal Tab on Back Panel
NOTE: The green ground wire terminal can
be attached when reassembling the back
plate to the drawer cavity.
Un-hook Black AC Wire to Top Terminal
Un-hook White AC Wire to Bottom Terminal
Noise
Filter
(mounted
on rear
base plate)
Figure 1
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug microwave drawer or disconnect
power.
2. Follow procedures to remove the
back panel as outlined in the steps
under“ACCESSING INTERNAL COM-
PONENTS” pages 4-2 and 4-3.
3. Un-hook the black and white AC ter-
minals from the Noise Filter and green
ground wire from the back plate,
see figure 1 & 2.