Karassn KS-200B Series User Manual - page 8
100-Zone Wireless Alarm System
-
7
-
Interface Of DC:
V+and C end provide other devices with+12V-13.8V300mA
DC output. V+end is anode of DC, and C end is cathode of DC.
2 DC Input:
Interface of +12V DC input, the polarity is .When it needs to
collocate with large capacity battery, it can be connected with backup power. This
interface has self-charge device and it can automatically between AC and DC. This
interface should not be short-circuit. If build-in backup battery is adopted, this
interface should not be connected with power.
3 Power Switch:
When it is turned off, the main unit doesn’t work, but backup
battery still self charge with AC power.
4 Fuse:
AC powr fuse, it is AC 220V1A tube fuse.
5 AC Power Input:
It adopts AC 220V 50Hz.
6 Extension Socket:
It connects with telephone set.
7 Outside Line Socket:
It connects with outside line
5.2 KS-200AT Wireless PIR Detector
It sends alarm signal once when it is powered on.
1 Infrared Sensitivity Selection: If the jumper is inserted at “H” position, the
distance it can detect is 8 to 12 m. If the jumper is inserted at “L” position, the
distance it can detect is about 4 to 8 m. Lower sensitivity is
recommended under satisfaction.
2 Backup Power Input: There are floating charge devise,
if backup battery is not selected, it can be connected with
rechargeable battery or storage cell and allowable voltage
of input power is DC 12-13.8V.
3 AC Power Input.
4 Forced Emit Control: If it is short-circuit, the detector
will continuously send alarm signal till the jumper is
disconnected. Usually, it is used to test whether the emission circuit is normal.
5 Double PIR Sensor: The surface should be kept clear and it is not allowed to
touch the surface by hand. If the surface is dirty, clear it with a cotton ball dipped
、
、
、
、
、
、
、
、
、
、
、
1
2
3
4
P US E
P US E
4
1
2
3
4
P US E
P US E
5
2
3
6
7
C
V+ V+
H
L
100-Zone Wireless Alarm System
-
18
-
Press 12# # to delete the 2nd group of informed telephone number.
Press 13# # to delete the 3rd group of informed telephone number.
Press 14# # to delete the 4th group of informed telephone number.
Press 15# # to delete the 5th group of informed telephone number.
Press 16# # to delete the 6th group of informed telephone number.
Press 17# # to delete the 7th group of informed pager number.
Press 18# # to delete the 8th group of informed pager number.
Press 19# # to delete all 8 groups informed telephone numbers.
(5) How To Record
Press 30 #, after hearing indicative “beep” sound, aim at the Microphone on the
front panel to speak what you like. The record time should not beyond 10 seconds,
Press # to finish. If the record is beyond 10 seconds or don’t press “#” key to stop
after 10 seconds, it will cause the un-completion or loss. You should record it again.
Each time enter this operation, the original voice will be lost. But the latest
record will be save permanently if no power failure.
(6) How To Play Record
Press 31# to play your record for 10 seconds at most. After 10 seconds, there is an
indicative “beep” sound, then you can go on other operations.
(7) How To Operate When Receiving Alarm Telephone Numbers
While receiving alarm, pick up telephone receiver, it will report in pure English to
tell you “which zone” occurs alarm. After an indicative “beep” sound,
press:2#------to stop alarming and stop dialing other inform telephone numbers.
5#-----re-play alarm record
If your command is effective, there should be an indicative “beep” sound, or you
have to press again.
E.g. There is alarm occurs in the 25th zone at No.3 building in XX garden. When
answering alarm telephone, you will hear the voice alert “Ding dong, attention
please!!! the 25th
zone occurs the anti-theft alarm, please do some effective operations quickly!!!”.
( is what you pre-record). After hearing the voice alert, you will hear an
indicative short “beep” sound, the system will wait for 20 seconds to receive
commands. Enter“5#”to replay if the alarm voice is not clear. After an indicative
short“ beep” sound, enter“2#”to stop alarming, and stop dialing other alarm
telephone numbers. If there are no operations within 20 seconds, the main unit