Karassn KS-200B Series User Manual - page 9
100-Zone Wireless Alarm System
-
17
-
Press 11# CCCCCC # to set the 1st group of informed telephone number.
Press 12 # CCCCCC # to set the 2nd group of informed telephone number.
Press 13 # CCCCCC # to set the 3rd group of informed telephone number.
Press 14 # CCCCCC # to set the 4th group of informed telephone number.
Press 15 # CCCCCC # to set the 5th group of informed telephone number.
Press 16 # CCCCCC # to set the 6th group of informed telephone number.
Press 17 # CCCCCC # to set the 7th group of informed pager number.
Press 18 # CCCCCC # to set the 8th group of informed pager number.
The above “CCCCCC” is the telephone (or mobile phone or pager) number.
Note:
1
、
During the course of entering telephone numbers (mobile phone, pager), Use a
“*” as a pause for two seconds. The number of * is subject to the type of telephone
exchanger, e.g.: mobile phone, group telephone. Semi-automatic pager station, etc.
2
、
Each group of number (including *) should not beyond 27 digits.
3
、
It is unnecessary to enter superabundance phone numbers. If wrong numbers
has been entered, it can be directly cover with or be deleted.
4
、
When alarm host dials the pager. It will automatically add the signal code. But
it should be operated according to the local pager station formula.
E.g.: How To Set Pager In Middle Northern Of Quanzhou City
Press “95951 1234567”, there is indicative voice “hang up to answer the same
phone number, information code press 1 and press # to finished”. So the users shall
be enter into “1”, the pager formula as follows”
17#959511234567* * * * * * 1 * * #
The above * is a pause. Every * has 2 seconds pause time. The * number is subject
to time of the pager indicative voice.
E.g.: If the users want to set the first group telephone number to be “1234567”,The
second group to be “1234567” with the extension number is 801,the third group to
be 13900000012.
You can press as following:
11#1234567#
12#1234567**801#
13#13900000012#
(4) How To Delete Informed Telephone Numbers
Press 11# # to delete the 1st group of informed telephone number.
100-Zone Wireless Alarm System
-
8
-
in 90% alcohol.
6 Alarm Indicator: It lights when emitting alarm signal. Usually, to protect
wireless emission circuit, the alarm emission duration is controlled within 5
seconds, and the alarm interval is about 10 seconds. During the alarm interval
duration, the infrared detector doesn’t respond to alarm signals.
5.3 KS-200ACT Series Wireless PIR Detector
When KS-200ACT wireless PIR detector is powered on, it will be automatically
blocked for 20 seconds and won’t receive infrared signals. After 20 seconds, it will
automatically enter arm state.
1 Forced Emit Control: If it is short-circuit, the
detector will continuously send alarm signal till the
jumper is disconnected. Usually, it is used to test whether
the emission circuit is normal.
2 Infrared Sensitivity Selection: If the jumper is
inserted at “H” position, the distance it can detect is 8
to 12 m. If the jumper is inserted at “L” position, the
distance it can detect is about 4 to 8 m. Lower sensitivity
is recommended under satisfaction.
3 AC Power Input.
4 DC Input: There are floating charge devise, if backup battery is not selected,
it can be connected with rechargeable battery or storage cell and allowable voltage
of input power is DC 12-13.8V.
5 Double PIR Sensor
6 Transmit Address Code: It is used to change the address code of detector, and
only KS-200ATI,KS-200BTI have this function. They can transmit the signal of
KS-200DCT wireless PIR detector, KS-20BW wireless door sensor, smoke
detector to KS-200B-A/B series main unit.
7 Arm Indicator: It lights when it is in arm state, which means it enters defense
state, only KS-200ATI, KS-200BTI detectors have this function.
8 Alarm Indicator: It lights when it alarms.
5.4 KS-200ATI Wireless PIR Detector
Base on KS-200ACT, KS-200ATI wireless PIR detector increase functions to
arm/disarm/emergency alarm and transmit wirelessly. The detector is blocking by
itself for 20 seconds when powered on. And during the time, it doesn’t receive any
、
、
、
、
、
、
、
、
、
1
8
9
6
L
H