National Instruments NI 9516 Operating Instructions And Specifications - page 30
30
|
ni.com
|
NI 9516 Operating Instructions and Specifications
Low, VOL
Sinking 12 mA ..................... 0.7 V max
Sinking 4 mA ....................... 0.5 V max
Compare mode ........................... Software-selectable: single
or periodic
Compare action .......................... Software-selectable: set,
toggle, or pulse
Max compare rate (periodic) ...... 5 MHz
Pulse width (programmable)
Min....................................... 100 ns
Max ...................................... 1.6 ms
Active state................................. Software-selectable: high or
low
Digital Inputs
Number of inputs .............................. 2
Input type.......................................... Software-selectable: sinking
or sourcing
Digital input configured for sinking
Digital logic levels, OFF state
Input voltage ........................ ≤5 V