x Sealing Kit mounting
- The kit consists of a gasket, 4 small O’rings and a pot of grease.
- Ensure that the surface to be in contact with the back of the frame, and thus the gasket, is plane and has
been cleaned, prior to firmly flush mount the Monitor in place.
- The gasket must be positioned totally into the surrounding groove at the back of the Monitor’s frame. Cover
both the gasket and the front evenly with grease. Position carefully the monitor in the panel cut out, and
adjust the edge of the gasket so that it levels the front.
- Position the 4 small O’rings into their respective screw holes, grease slightly every one of them before
tightening the 4 front screws.
1.6 Electrical installation
- All electrical connections are to be found on the lower back side of the Monitor. All necessary electrical
indications are to be found on the Terminal Plate at the bottom of the Monitor’s backside.
- May the Monitor be exposed to severe vibration or shocks, all electrical cables can firmly be maintained in
position, using the 2 black plastic cable retainers.
Figure 1. Terminal Plate for a 19” Sea Line Monitor.
x Power supply
- The Monitor can be supplied with 115/230 VAC and/or 24 VDC. The AC voltage can be selected on a slide
switch placed between the AC and DC input connectors. The lower position (by default) selects 230 VAC
while the upper position selects 115 VAC.
- The Monitor is connected to AC voltage by means of the standard AC power cable included in the delivery.
The AC current to the Monitor must be limited by a 10A fuse or similar.
- The Monitor is connected to DC voltage by means of the DC power plug included in the delivery and wires
suitable for up to 8 A. The Monitor will not be damaged by reversed polarity, may it occur.
x Earth connection
- On the Terminal Plate an icon, marked with an earth symbol, is presented for placing of the earth connection
screw, allowing safe earth connection. Please use a cable of minimum 1.3 mm
2
(16 AWG) with crimp
terminals.
- Remember to fasten the earth connection screw for adequate earth connection.