Set DTR Alarm, information includes (Fig. 24):
> Graphics SEt and DTR -
> Time Value (min) flashing with min icon
• A (hold) to scroll upward through Set Points at a rate of 8
per second from OFF to 5 through 20 (min) in increments
of 1 min.
• A (< 2 sec) to step upward through Set Points one at a time.
• S (< 2 sec) to save the setting and access Set PO2 Alarm.
• S (2 sec) to revert to Set TLBG Alarm.
Set PO2 Alarm, information includes (Fig. 25):
> Graphic SEt with NX icon
> Set Point value (ATA) flashing with PO2 and MAX icons
• A (< 2 sec) to step upward through Set Points from 1.20 to
1.60 one at a time.
• S (< 2 sec) to save the setting and revert to the Set A Menu.
• S (2 sec) to revert to Set DTR Alarm.