Oceanic VEO 2.0 Operating Manual - page 44
44
CLEAR (RESET)
The VEO is configured with a feature that allows data to be cleared, including nitrogen
and oxygen calculations and Log entries. This is intended for facilities using the VEO for
rental or training activities, not for general use by individual divers.
WARNING: Reset after a dive and subsequent use for a repetitive
dive conducted by the same diver could result in serious injury or
death.
Upon access, a factory assigned code number is displayed with the graphics CLR and id,
all solid (Fig. 45).
Reset procedure:
• S (2 sec), at any time, to cancel the procedure and revert to the SN screen.
• S (< 2 sec) to start the first 2 digits (left) flashing.
• A (hold) shall scroll upward through the first digits (left) at a rate of 8 per second.
• A (< 2 sec) shall step upward through the digits (left) one at a time.
• S (< 2 sec) shall save the first 2 digits (left) and the second 2
digits (right) shall flash.
• A (hold) shall scroll upward through the second digits (right)
at a rate of 8 per second.
• A (< 2 sec) shall step upward through the digits (right) one at
a time.
• S (< 2 sec) shall save the Reset Code, Clear the unit, and turn
it Off.
Fig. 45 - CLEAR