Fig. 73 - PO2 ALARM MAIN
PO2 Alarm Main, information includes (Fig. 73) -
> NX icon
> Current Depth with FT (or M) icon
> DTR with NDC (or O2) and min icons
> PO2 value (ATA) with PO2 icon, flashing until < Set Point,
then solid
> Up Arrow icon, flashing until < Set Point, then solid
> TLBG with icon
> VARI while ascending
> (PZ+), CF icons - those that apply
• A (< 2 sec) to access ALTs (similar to those for No Deco).
• S (< 2 sec) to activate Backlight.
High PO2 during Deco (Fig. 74)
The PO2 alarm setting does not apply when in Deco.
> If PO2 reaches 1.60 while at a Deco Stop, the PO2 value
(1.60) with icon will alternate with Deco Stop Depth/Time
once each minute*.
*PO2 on for 10 seconds, Deco Stop Depth/Time on for 50 seconds
until PO2 decreases below 1.60, then PO2 will not be displayed.
Fig. 74 - PO2 ALARM
(while in Deco)
alt w/ Stop
Depth/Time