Oki MC770 series Maintenance Manual - page 84
45376001TH Rev.1
83 /
Oki Data CONFIDENTIAL
4. Component replacement
4.2.16 Hopping motor/ Fuse motor
(1) Open the scanner and top cover.
(2) Remove the plate shield and take the CU/PU PCB out. (See section 4.2.9)
(3) Remove the Plate-Board-R-Assy.(See section 4.2.11)
(4) Remove the two screws ① (silver, No:42920428) and connector, and take the
low voltage FAN ② out.
(5) Disengage the claw D (2 places) and claw E, and remove the motor cover ③ .
(6) Remove the two screws ④ (silver, No:42920406) and connector, and take the
hopping motor ⑤ out.
(7) Remove the four screws ⑥ (silver, No:42920406) and connector, and take the
fuse motor ⑦ out.
(8) Remove the three screws ⑧ (silver, No:42920406) and connector, and take the
ID motor ⑨ out (2 places).
Notes!
• BecarefultoinstallthelowvoltageFAN ② in the proper direction.
①
×2
②
③
④
×2
⑤
⑥
×4
⑦
⑧
×3
⑨
⑧
×3
⑨
Claw D
Claw E
Air