WEG CFW-11 User Manual - page 108
Technical Specifications
8
8-2 | CFW-11
Table 8.1 - Technical specifications of the CFW-11 inverter series frame sizes F, G and H models at rated switching
frequencies
Model
CFW11
0242 T 4
CFW11
0312 T 4
CFW11
0370 T 4
CFW11
0477 T 4
CFW11
0515 T 4
CFW11
0601 T 4
CFW11
0720 T 4
CFW11
0760 T 4
CFW11
0795 T 4
CFW11
0877 T 4
CFW11
1062 T 4
CFW11
1141 T 4
Frame Size
F
G
H
Number of P
ower Phases
3Φ
Use with Normal Duty
(ND) Cycle
Rated Output Current
(1)
242
312
370
477
515
601
720
760
795
877
1062
1141
Overload
Current
(2
)
[Arms]
1 min
266
343
407
525
567
662
792
836
875
965
1168
1255
3 s
363
468
555
716
773
900
1080
1140
1193
1316
1593
1712
Rated Switching F
requency [kHz]
2
2
2
2
2
2
2
2
2
2
2
2
Maximum Motor
(3
)
[HP/kW]
200/150
250/185
300/220
400/300
400/300
500/370
600/440
650/480
700/515
750/560
950/700
1000/750
Rated Input Current
242
312
370
477
515
601
720
760
795
877
1062
1141
Dissipated
Power [W]
Surface
Mounting
(4
)
2651
3957
4578
6059
6490
7044
8532
10055
9851
10993
12498
13558
Flange
Mounting
(5
)
622
826
900
1227
1339
1584
1685
2008
755
759
764
768
Use with Heavy Duty
(HD) Cycle
Rated Output Current
(1)
211
242
312
370
477
515
560
600
637
715
855
943
Overload
Current
(2
)
[Arms]
1 min
317
363
468
555
716
773
840
900
956
1073
1283
1415
3 s
422
484
624
740
954
1030
1120
1200
1274
1430
1710
1886
Rated Switching F
requency [kHz]
2
2
2
2
2
2
2
2
2
2
2
2
Maximum Motor
(3
)
[HP/kW]
175/132
200/150
250/185
300/220
400/300
400/300
450/330
500/370
550/400
600/440
750/560
800/590
Rated Input Current [Arms]
211
242
312
370
477
515
560
600
637
715
855
943
Dissipated
Power [W]
Surface
Mounting
(4
)
2296
3046
3829
4669
6005
6005
6589
7909
7824
8836
9916
11022
Flange
Mounting
(5
)
524
614
722
915
1232
1320
1253
1550
747
751
753
757
Surrounding Air T
emperature [ºC (ºF)]
-10...45 ºC
(14...113 ºF)
-10...40 ºC
(14...104 ºF)
RFI Filter
Built
-in
W
eight [kg (lb)]
130
132
135
140
204
207
215
215
213
213
220
220
A
vailability of Option Kits
that can be Integrated
into the P
roduct (refer
to the smart code in the
Section 2.5 HOW T
O
SPECIFY THE CFW
-11
MODEL (SMAR
T CODE)
on page 2-14
)
Safety Stop
Ye
s
24 Vdc External Control P
ower
Supply
Ye
s