Wood Stone WS-MH-RFG-IR Installation And Operation Manual - Very Important!
Questions? Call Wood Stone at 800-578-6836
11
MH-RFG-IR Installation and Operation Manual
September
2006
VERY IMPORTANT!
WOOD STONE RECOMMENDS THAT YOU SUBMIT YOUR
VENTING PLANS TO LOCAL CODE AUTHORITIES
BEFORE PROCEEDING WITH INSTALLATION.
It is never appropriate to use “B vent” in any part of an exhaust system
connected to a Wood Stone Appliance.
All ducting material must be
manufactured to the specifications of a grease duct. Due to the possibility
of sparks entering the duct, exhaust systems serving solid-fuel equipment
SHOULD NOT be combined with exhaust systems serving other (non-solid-
fuel) equipment.
OVEN VENTING (continued)
Views of installation of a Wood Stone hood. Note that the notch of the hood is even
with the front edge of the oven. Hood may be moved forward slightly if needed. The
hood should be installed in accordance with the hood manufacturer's instructions, and
with NFPA 96 and/or the applicable local and national codes.
Allow 8"min. opening
between any facade
and the inside edge
of the front of the
hood to allow for filter
removal.
8"