Wood Stone WS-MH-RFG-IR Installation And Operation Manual - Gas
Questions? Call Wood Stone at 800-578-6836
7
MH-RFG-IR Installation and Operation Manual
September
2006
GAS
The Wood Stone Gas ovens are equipped with a 3/4" NPT gas connection.
Have a licensed gas installer provide the hook-up and test all fittings and
pipe connections for leaks. Use approved gas leak detectors (soap solutions
or equivalent) over and around the fittings and pipe connections. DO NOT USE
FLAME TO TEST FOR LEAKS!
SV-1 and SV-2 are the gas control valves that operate under floor infrared
burner and the interior radiant burner, respectively. SV-1 is located directly behind
the service/ intake panel and in front of the under floor infrared burner. SV-2 is
located under the oven to the rear left.
The manifold pressure test port for the infrared under floor b u r n e r
is a 1/8" NPT plugged tapping located near the left end of the burner
manifold.
The manifold pressure test port for the radiant (interior) burner is
a 1/8" NPT plugged tapping located at the base of the T-junction between
the SV-2 and the radiant/interior burner. When checking this pressure, make
sure the flame is turned up to its maximum height using the knob on the
front of the oven.
The burner manifold pressures have been adjusted and tested at the factory. A
variety of factors can influence these pressures, so be sure to test the individual
burner manifold pressures and adjust the valves as necessary to achieve the
required pressures. Note: The gas valves are shipped in the 'on' position.
Factory specified individual burner manifold pressures for models
equipped to burn Natural Gas.
MODEL
SV-1 SV-2
WS-MS-4-RFG-IR-NG
3.5" 5"
WS-MS-5-RFG-IR-NG
3.5" 4.75"
WS-MS-6-RFG-IR-NG
3.5" 4.75"
WS-MS-7-RFG-IR-NG
3.5" 4.6"
Factory specified individual burner manifold pressures for models
equipped to burn Propane (LP).
MODEL
SV-1 SV-2
WS-MS 4-RFG-IR-LP
9"
7"
WS-MS-5-RFG-IR-LP
9"
8"
WS-MS-6-RFG-IR-LP
9"
8"
GAS SPECIFICATIONS
WS-MS-7-RFG-IR-LP 9.2" 9.5"