Wood Stone WS-MH-RFG-IR Installation And Operation Manual - Oven Operation
Questions? Call Wood Stone at 800-578-6836
19
MH-RFG-IR Installation and Operation Manual
September
2006
OVEN OPERATION
4. ADJUSTING THE FLOOR SET-POINT
To adjust the thermostatic floor temperature setting, simply press the
arrow button corresponding to the direction in which you would like the setting
to go. If the thermostatic set point is raised above the actual hearth temperature,
the underfloor burner should activate.
* It is only possible to program the floor’s thermostatic hearth set point to
temperatures from 200 to 700 degrees F. Once proper temperatures for your
application have been established, there should be little or no need to change
the hearth set point.
For additional operational and cooking information please visit
www.woodstone-corp. com or call Wood Stone!
NIGHT DOORS: The door(s) are used for nighttime heat retention.
Do not
operate the appliance with doors in place.
Night Doors
WARNING: Never use this appliance as a space heater to heat or
warm up the room. Doing so may result in carbon monoxide
poisoning and overheating of the appliance.
To avoid an accidental fire do not use the cooking chamber for
storage space.