Zebra CPCL Programming Manual - Set-Tof Command
P9-12
Mobile Printer CPCLProgramming Manual
SET-TOF Command
This command is used to program the distance be-
tween the top-of-form and the end of the next (positive
value) or previous (negative value) eye-sense mark or
gap. The eye-sense-mark or gap that is closer to the top-
of-form should be used for top-of-form setting.
Format:
{command} {d}
where:
{command}:SET-TOF
{d}: The distance between the top of form and the
end of the next or previous eye-sense mark or gap,
which ever is closer. The specified value should be
negative if the previous eye-sense mark is used as
reference, or positive if the next eye-sense mark is
used.
The following are the maximum values (in DOTS) that
can be specified for each model in Zebra’s Mobile Printer
line:
Cameo 2 & 3 ................. 79
Encore 2& 3 .................. 119
Encore 4 ....................... 127
MP5022 & MP5033 ....... 101
MP5044 ........................ 133
QL 220 .......................... 89
QL 320 .......................... 116
QL 420 .......................... 106
RP3 ............................... 142