Zebra CPCL Programming Manual - Ip.Pop3.Poll
P14-48
Mobile Printer CPCLProgramming Manual
ip.pop3.poll
type: getvar; setvar
This parameter refers to the frequency (in seconds) that
the printer will query a POP3 mailbox for new mail. This
only applies if the ip.pop3.enable is set to “on”.
NOTE: A poll value of less then thirty seconds is not recommended. The
printer is unresponsive for several seconds when polling for email depending
on data transfer time from the server to the printer.
get var results
This will return the poll frequency in seconds
Example
Description
This command instructs the printer
to respond with the POP3 poll fre-
quency (in seconds).
Syntax
! U1 getvar “ip.pop3.poll”
Result
“240”
set var choices
“0” through “65535” A value of “0” will cause the
printer to only query the POP3 mailbox once on
printer power up.
Default
“240”
Example
Description
This command instructs the printer
to poll the POP3 mailbox every four
minutes.
Syntax
! U1 setvar “ip.pop3.poll” “240”
Result
This will set the pop3 polling fre
quency to 240 seconds (4 min-
utes).