module baseline set
133
3500
✓
9000
9400
3900
9300
module baseline set
Resets the baseline counters to zero and time-stamps the baseline.
Valid Minimum Abbreviation
mo ba set
Important Considerations
■
Baselining is automatically enabled when a baseline is set.
■
The module maintains the accumulated totals since power-on.
■
After you disconnect from a module on which you set a baseline, the
baseline is disabled. You must reconnect to that module and use the
module baseline
requestedState
option to reenable the baseline.