3Com CoreBuilder 9000 Command Reference Manual - page 134
Other manuals for CoreBuilder 9000:
Manual, Removal And Replacement Manual, Device View User Manual, Installation Manual, Installation Manual, Quick Start Manual, Quick Installation Manual, User Manual
Manual is about: 3Com Switch Command Reference Guide
of
784
134
C
HAPTER
4: M
ODULE
E
NVIRONMENT
module baseline
3500
✓
9000
9400
3900
9300
requestedState
Enables or disables a baseline.
Valid Minimum Abbreviation
mo ba req
Important Considerations
■
When you reenable a baseline, the counters return to the values that
have accumulated since the most recent baseline that you set.
■
Disabling a baseline returns the counters to the total accumulated
values since the last power on.
■
After you disconnect from a module on which you set a baseline, the
baseline is disabled. You must reconnect to that module and use the
module baseline
requestedState
option to reenable the baseline.
Options
Prompt
Description
Possible Values
[Default]
Baseline
Whether you want to enable or
disable the baseline
■
enabled
■
disabled
disabled