Baldor MicroFlex e100 Installation Manual - page 128
www.baldormotion.com
A-4 Accessories
MN1942
A.1.4 EMC filters
AC filters remove high frequency noise from the AC power supply, protecting the
MicroFlex e100. These filters also prevent high frequency signals from being transmitted back
onto the power lines and help meet EMC requirements. To select the correct filter, see sections
3.4.7 and 3.4.8.
A.1.4.1 Catalog numbers
Baldor
catalog number
Rated volts
Rated amps
@ 40°C
Leakage current
(mA)
Weight
kg (lbs)
FI0014A00
250
3
0.4
0.27 (0.6)
FI0015A00
250
6
0.4
0.45 (0.99)
FI0015A01
250
10
0.4
0.73 (1.61)
FI0015A02
250
12
0.4
0.73 (1.61)
FI0018A00
480
7
33
0.5 (1.1)
FI0018A03
480
16
33
0.8 (1.76)
FI0029A00
250
22
33
3.0 (6.6)
B
M5
A
F
C
E
D
G
Dimensions mm (inches)
Dimension
FI0018A00
FI0018A03
A
190 (7.48)
250 (9.84)
B
160 (6.30)
220 (8.66)
C
180 (7.09)
235 (9.25)
D
20 (0.79)
25 (0.98)
E
4.5 (0.18)
5.4 (0.21)
F
71 (2.80)
70 (2.76)
G
40 (1.57)
45 (1.77)
Figure 56 - Filter dimensions, types FI0018A00 and FI0018A03