NEC SL2100 Installation Manual - page 10
10 |
P a g e
Installation
Connecting the ISDN Call Recorder.
The call recording unit can be rack mounted, free standing or mounted in a CD / DVD ROM bay of a
PC. The patch leads connecting through the tap connector should each be no longer than 10 metres
in length. The USB lead supplied with the call recording unit is 1 metre in length. This will mean the
call recording until and PC will have to be situated near each other.
The ISDN lines are connected from the NTE into the tap connector supplied with the call recording unit.
A cable should then run from the other socket on the tap connector to the ISDN card in the PBX. Once
both are connected, calls will be able to pass through the tap connector. There are different types of
tap connectors, one for BRI and one for PRI. The PRI is black and the BRI is white, both are clearly
labelled and can only be used on their respective call recorder.
Once the lines are connected through the tap connector, the other two cables labelled in and out should
be connected to the front of the call recording unit accordingly. Securely connect the supplied power
adapter to the call recording unit and firmly connect the supplied USB lead to the rear of the call
recording unit. Connect the USB lead to the PC until before installing the call recording software. If the
operating system starts the new hardware found wizard, click cancel.
Print Server
Link/Rx
LPT1
LPT2
COM
Power/TX
PSTN
Tap Connector
Call Recorder
In Out