Oce Arizona T220 User Manual - page 15
General Description |
10/16/03
1-3
1.1.3
Vacuum Pump Power Requirements
The vacuum pump operates over the following range of voltages and frequencies:.
230 Volts @ 60HZ
Voltage:......................230 VAC +/-10%, 3 Phase
Current:......................14 AMPS maximum steady state
Power: .......................7kW max.
Circuit Breaker...........20 Amps
400 Volts @ 60Hz
Voltage:......................400 VAC +/-10%, 3 Phase
Current:......................7 AMPS maximum steady state
Power: .......................7kW max.
Circuit Breaker...........15 Amps
190 Volts @ 50 Hz
Voltage:......................190 VAC +/-10%, 3 Phase
Current:......................16.5 AMPS maximum steady state
Power: .......................7kW max.
Circuit Breaker...........20 Amps
380 Volts @ 50 Hz
Voltage:......................380 VAC +/-10%, 3 Phase
Current:......................8 AMPS maximum steady state
Power: .......................7kW max.
Circuit Breaker...........15 Amps
Note:
ODGS recommends that the AC power outlet for the vacuum pump be
located within 8 feet of the power inlet on the pump.
Important: Unplugging the power cord from the wall socket is the only way to
isolate the entire machine.