Gray Balance
Obtain good gray results by individually setting the ink restriction
value of each color (maximum deviation between colors should
be <= 30%), then using the Gray Balance Linearization in
PosterShop.
Also, grays will tend to have a green/yellow cast if the drying
temperature is too low.
Long USB Cable for
Eye-One
Spectrophotometer
We recommend that you purchase a 16’ USB cable (maximum
USB cable length spec.) or a 10’ USB cable extension for use
with the Eye-One Spectrophotometer.
Ideal operating Ink
Temperature
The recommended operating range of ink temperature is 32C to
38C (90F to 100F).
Exporting
Spectrophotometer
Readings
When making a media model (linearization) or ICC profile we
recommend that the Eye-One Spectrophotometer readings are
exported immediately after reading the patch values. The
reason is that if the patch readings are saved and backed up,
profiles can be reconstructed at a later date if required.
Using Menu key
when altering
offsets, height or
heat
If the + key is pushed to modify offsets, carriage height or heater
duty cycle, pushing the Accept key will advance the cursor to the
next digit of the current parameter. However if no changes are
desired for this parameter pushing the Menu key will advance to
the next parameter.
Situation
Recommendation