Oce Arizona T220 User Manual - page 97
Weekly Maintenance |
10/16/03
7-85
plastic capping station and the smaller pads, which have rounded corners, are
used in the aluminum capping stations.
Safety Information
Use appropriate safety equipment — butyl gloves, eye protectors, and respirator.
Procedure:
1.
Use the Access Carriage command from the control panel to automatically move
the carriage to the blotting station (see Figure 4 on page 14).
2.
Open the gantry doors to access the capping station.
3.
Use protective butyl gloves in case of contact with ink or solvent.
4.
Inspect the foam capping pads and replace any that appear to be worn. Also check
that the pads are positioned squarely in their slots.
5.
Saturate any new pads with solvent until they expand fully.
6.
Close the gantry doors and use the Park Carriage command from the control panel
to automatically move the carriage back to the capping station.
Warning:
Make sure that no foreign debris is allowed to fall into the Waste Ink
Tray as this could block the drain and cause it to overflow.