Oce Arizona T220 User Manual - page 82
Océ | Troubleshooting
6-70
3010100686-B
Vacuum squeals when
turned on
If the vacuum squeals when turned on, adjust the
vacuum hose to change the airflow, until the noise is
eliminated. Try a tight coil in the hose. Once a good
hose position has been determined use duct tape to hold
the hose in place.
Also, check hose clamps to verify they are tight and
check that all connections are secure.
Mist of Stray Ink
Very fine ink droplets that have no directionality (looks
like solar wind), may be caused by static electricity. Use
an anti-static device on the media or clean the media
with isoprophyl alcohol to reduce static.
Carriage crashing into the
Media
If a media collision error occurs, fix the obstruction if
easy to do so, then cancel the print. However if the
media is wedged between the carriage, do not attempt
to remove the jammed media, this could possibly
damage the print heads. Instead reboot the printer as
this will automatically raise the carriage to the highest
possible position during the reboot sequence so the
media can be removed.
Carriage is not capped
after a running a nozzle
print or doing
maintenance.
This is normal, as sometimes it is desired not to cap
after doing maintenance. However, if the carriage is
positioned over the capping station it is autocapped after
5 minutes.
SCSI ID 5 Oce Arizona
T220 ASYN – Start Unit
Request Failed (Error
Message on computer
boot-up)
The error is caused by booting the computer after the
T220 printer has been powered up but prior to it being
online. Reboot the computer after the T220 printer goes
online.
Control Panel Menu
cycles on it’s own
This is a VRC board problem that was fixed in Firmware
1.5.3. Make sure that the installed firmware is at leat that
revision or higher..
Problem
Solution