Saeco Cappuccino Service Manual - page 75
ROYAL
5. SERVICE PROGRAMME
Saeco International Group
REV.4 SEPT.2003
Page 5/24
2.2. Diagnosis menu
(Royal Digital / Exclusive / Digital Redesign)
The values below can be read and adjusted in the diagnosis menu as shown in the table.
Access:
The following button combinations can be used in standby mode to access the diagnosis
menu as indicated in the table below.
TYPE
Press simultaneously
Whilst pressing
Digital / Exclusive
EXPRESSO LUNGO
EXPRESSO
STEAM
STANDBY
Digital Redesign
EXPRESSO LUNGO
Powder coffee
EXPRESSO
COFFEE
(The user programme is also available in this mode.)
Using the
button scroll to the menu item "Diagnosis" and confirm via the ENTER button.
Changing programme values:
Access appropriate item using the ENTER button.
Change value with ARROW buttons
Save value by using the ENTER button.
Programme table (diagnosis menu)
Function/Standard
Setting range
Increment
Comments
EXPRESSO LUNGO
No. of PULSES 600
50 – 1,000 Pulses
+/- 1
EXPRESSO
No. of PULSES 195
50 – 1,000 Pulses
+/- 1
COFFEE
No. of PULSES 360
50 – 1,000 Pulses
+/- 1
Number of flow meter pulses for
each saved cup fill volume, where
300 pulses correspond to approx.
100 ml.
----HEATING----
PARAMETER K1 7
1 – 50
+/- 1
Do not change!
----HEATING----
PARAMETER K2 30
1 – 50
+/- 1
Do not change!
NORMAL TEMP.
° C 86
70- 130°C
+/- 1
Normal temperature is used if not
more than 6 min. have elapsed
since last coffee dispensed.
HIGH TEMP.
° C 92
70- 130°C
+/- 1
If no coffee is dispensed for an
extended time (over 6 min.), the
next coffee will be heated to a
higher temperature to compensate
for cooling of the brewing unit and
the associated temperature loss.
TEMP.OF 1st COFFEE
° C 94
70- 130°C
+/- 1
Used when dispensing the first
coffee after the machine has been
turned on, to compensate for the
high temperature loss due to the
cold brewing unit and water pipes.