BOV/HOSE ASSEMBLY
• Connect the LP feed, which should be over the diver’s right shoulder, to
the BOV. Replace the LP hose end O-ring if required.
• Fit the breathing hose with the white silicone hose covers to the left hand
side (inhalation side) of the BOV.
• Repeat for the right hand side (black) hose.
!
NOTE: The BOV should be connected to the weighted side of the
breathing hoses.
BOV/HOSE ASSEMBLY TESTING
In open-circuit mode, immerse the BOV. Block the exhalation hose end
(black) and blow into the inhalation hose end (white).
Faults:
• If bubbles come out of the mouthpiece there may be a leak in the barrel/
knob O-rings. They must then be replaced.
EXPLORER LSS MODULE - DISASSEMBLY/ASSEMBLY
• Remove the LSS Module by twisting the lock ring counterclockwise ½
turn.
• Inspect & clean O-ring and sealing surfaces, re-lubricate and refit the
LSS Module sealing O-rings.
• Refit the LSS Module by lining up the solenoid post, pushing it into the
Canister, and turning the lock ring clockwise by 180 degrees to 3 O’clock
(Fig.
2.16).
!
NOTE: Ensure the lock ring is in the 9 O’clock position for the
threads to engage then twist it by 180 degrees to 3 O’clock to
lock. The Case Back Cover will not fit correctly if the lock ring is
in the wrong position.
Fig. 2.16