Hollis Explorer User Manual - page 86
78 |
At the end of a successful Pre-dive sequence you will see the check
resources screen (Fig. 4.5).
At this point you should cycle through the screens by pressing the
left or right button to check that all resources are adequate to com-
plete the dive. After a few seconds the display will time-out to the Dive
screen (Fig. 4.6).
PRE-DIVE PRIMARY ERROR MESSAGES
The following are possible error messages that may occur during the Pre-
Dive Sequence and their meanings.
Message
Meaning
batteries at 10% - 30% power
Pre-dive and dive not permitted
until charged.
batteries at less than 10% power
Pre-dive and dive not permitted
until charged.
CO
2
sensor is unable to calibrate
and must be replaced or removed
(the 5 minute pre-breathe system
will be activated).
O
2
sensor(s) unable to calibrate
and must be replaced and/or their
connectors cleaned.
Fig. 4.5
Fig. 4.6