Decompression contingency
The EXPLORER is designed for recreational diving without decompression.
All dives however require safety decompression stops to be conducted
(consult your training agency for information).
If you accidentally stray into decompression the system will generate a
green/blue HUD alarm, the decompression stop, and stop time will be
displayed on the STATUS screen. This feature is designed for contingency
purposes only.
!
DANGER: The EXPLORER is not designed for use with gases other
than Nitrox.
! WARNING: Decompression diving significantly increases the risk
of decompression illness.
Various alarms will be generated if elements of decompression are vio-
lated. Please see the Deco States Table below and the EXPLORER flow
charts for further detail.
DECO STATES
State
Reason
HUD Color
Code
Status Screen
Display
Missed Stop
Missed deco stop
Blue/Green
MISSED STOP!
USE TABLES
Too Shallow
Deco Ceiling violated
for
Blue/Green
DECO!
DESCEND NOW
At Stop
Within 1 m/3.3 ft below
the next stop
Blue/Green
AT STOP
WAIT
x MINS
Near Stop
Within 3 m/10 ft
of the next stop
Blue/Green
NEAR STOP
ASCEND TO
x M (FT)
Too Deep
>3 m/10 ft below ceiling
Blue/Green
DECO!
ASCEND TO
x M (FT)
!
NOTE: When you have decompression stops to complete (or if
any alarm is showing) the STATUS display will remain on (and not
automatically time out).
3