Message
Meaning
Wireless HP sender battery is low.
Analyzed gas is not what is
expected by the DEFAULT GAS
setting.
Analyze gas and check setting.
The LCV and OPV are not vent-
ing at the correct pressure. Flush
valves with fresh water and repeat
test. If the problem persists return
the unit to your dealer.
You have stopped breathing while
conducting a pre-breathe se-
quence.
Repeat the test. If the error per-
sists return the unit to your dealer.
If the Predive sequence is com-
pleted, the STATUS window is
active, and you see the above
alarm, then HP usage is greater
than 1bar/min – 14.7 psi/min.
This could indicate a leak in the
HP or LP circuit (internal pipe-
work), BC or BOV. Submerge to
locate the leak.