HOW AUTO MODE WORKS
By setting ‘Auto’ DCP prior to diving the following events occur.
1. The DCP will automatically be set to 95% for the first 10 minutes of the
dive but only after the diver exceeds 10 m of depth.
2. If the NDL is then less than 60 minutes the DCP will stay set to 95% to
maximize the NDL.
3. If at any point on the ascent the NDL is in excess of 60 minutes then the
DCP will reduce to save gas and maintain the NDL at 60 minutes.
4. The minimum DCP is 10%. If the DCP is 10% and the NDL exceeds 60
minutes, the DCP will not decrease.
MANUAL MODE
In manual mode the diver can set the DCP using the screen shown (Fig.
3.19). A long hold of either the + or - button will jump the DCP value by 10.