9. Refill with Absorbent to the top. Tap down as required until you can fit
the lid. Refit the lid and the spring (under the yellow nut).
10. Screw down the top nut.
11. Wipe any dust from inside the canister.
12. Look into the Canister head and run your finger around the sealing
face for the quad-ring removing any debris.
13. Insert the filled Scrubber Pack into the Canister.
14. Refit the Right Hand end cap.
15. Dispose of old absorbent as normal household waste. Do not leave it
lying around for animals to ingest.
CO
2
ABSORBENT STORAGE
!
DANGER: Once a CO
2
Scrubber has been packed it should remain
so. Do not attempt to remove absorbent from a partly used scrub-
ber and dry it, refurbish or re-pack the absorbent in any way.
The scrubber should always be kept sealed until required for use. With
scrubber installed and not being used, the EXPLORER should have its
breathing loop closed. This is so that external air does not accelerate the
degradation of the scrubber. Additionally, the scrubber will continue to
degrade and change its characteristics post-dive if it has been activated/
used at all.
! WARNING: Once installed, the scrubber should always be
changed within 24 hours. Even if it has not been fully used
through breathing.