Hollis Explorer User Manual - page 28
20 |
• Flashing Green and Blue lights - warning is activated when a manage-
able error situation is in place. Refer to the wrist display, and take the
indicated action. If the issue can not be immediately remedied, the correct
response is to ascend slowly on the breathing loop while monitoring the
wrist display for escalating risk factors.
• Solid Green - means there are no detected problems
! WARNING: If any other light sequence or a ‘no light’ scenario is
experienced, then the diver should refer to the wrist display for
information, and abort the dive.
! WARNING: If no wrist display is seen, the diver MUST switch to
open circuit and ascend.
The LED states are configured for color blind as well as highly stressed div-
ers. The positions of the LED’s along with the flashing or solid state of the
lights provide conditions that cannot be confused with one another.
PRE-DIVE CHECKS
With current technology, not all aspects of the safety and working nature
of the EXPLORER system can be performed or determined automatically.
Therefore, when turning on the EXPLORER, there are a series of pre-dive
checks that must be performed. The EXPLORER gives guidance in per-
forming these checks. These checks are displayed in sequence on the
EXPLORER wrist display. Some of these checks rely completely on the
diver to perform them correctly – i.e. Close/open BOV. Other tests can be
performed by the electronics control system and the user needs to con-
firm that these are OK to dive with – i.e. that the high pressure cylinder is
adequately filled.
Information regarding the current status of EXPLORER and all available
resources can be reviewed prior to conducting Pre-Dive Checks using the
STATUS screen.