HANDLING ABSORBENT
! WARNING: CO
2
absorbent may cause burns to eyes and skin.
First aid treatment is as follows:
• Inhalation. Remove from exposure. Seek medical attention.
• Skin Contact. Drench with clean water and seek medical attention if skin
becomes inflamed.
• Eyes. Irrigate thoroughly with clean water. Seek medical attention.
• Ingestion. Wash out mouth thoroughly with clean water. Seek medical
attention.
See the brand respective safety data sheets for further safety information.
! WARNING: Always fill scrubber packs in a well-ventilated environ-
ment. Avoid contact with eyes and skin
.
FILLING STEPS – STANDARD VERSION
! WARNING: Filling a scrubber improperly could lead to a hypercap-
nia incident.
1. Remove the Scrubber Pack from the Canister. Inspect the quad ring for
cleanliness/damage and clean/replace with a small amount of lubricant
(Fig. 4.2).
2. Unscrew the yellow top nut and canister lid and inspect the canister
and lid mesh for damage.
3. Remove any excess absorbent stains from the canister components
with warm, soapy water and then rinse in fresh water. Then allow it to dry.
4. Place the Dust Filter inside at the base of the scrubber canister (Fig.
4.3). It should lay smoothly against the metal screen bottom with the tabs
along the radial edge folded upwards. Ensure that the tabs lay smoothly
against the inner walls of the scrubber canister.
5. Fill the canister in a well-ventilated environment. Raise the absorbent
barrel at least 200mm (8 inches) above the canister to allow dust to blow
away as you fill. Fill to the top of the canister, making sure absorbent is at
an even depth across the canister.
6. Pack the absorbent by tapping the sides for at least 1 minute.
7. Fill to the top again.
8. Pack the absorbent by tapping the sides for at least 1 minute
Fig. 4.3