65 of 100
2. Touch the
NEXT
push button to open the second screen.
➯ The following image appears:
1
2
3
This screen displays errors for the decoding ability:
①
Priority 1
Substantial transport stream errors, e.g. no image or fault
in the transmitter station (TS sync loss, sync byte error, PAT
error, continuity count error, PMT error, PID error)
②
Priority 2
Errors which apply to individual programmes; transport
stream is stable (transport error, CRC error, PCR error, PCR
accuracy error, PTS error, CAT error)
③
Priority 3
Application-dependent errors; predominantly NIT errors (NIT
error, SI repetition error, Unreferenced PID, SDT error, EIT
error, RST error, TDT error)
Reading the LED Display
LED colour
Meaning
green
No errors detected
red
Recently detected errors
orange
Errors detected in the past
black
Error detection not available