Encoder interface HTL input / HTL output
GB-6
2.3
Mechanical installation
All kind of works on the inverter may be carried out by authorized personnel in accordance
with the EMC and safety rules only.
• Switch inverter de-energized and await capacitor discharge time
• Pull off operator
• Remove plastic cover
• Remove fi xing bolt
• Fix interface board beginning from the socket connector straightly
• Screw in fi xing bolt
• Adjust desired supply voltage with DIL switch
• Attach plastic cover
3.
Description of the Interface
3.1
Voltage supply
Supply voltage for interface and encoders is made available by the frequency inverter. The
voltage to the encoder supply is switchable between 24 V (standard) and 15 V. An external
supply must be used if higher signal voltages or currents than mentioned below are re-
quired. The voltage input at X3B is used only for the HTL signal levels.
Figure 3.1 Voltage supply of control and encoder interfaces
U
int
24 VDC Internal voltage supply of COMBIVERT.
X2A
X3A
X3B
15V
15/24V
24V
U
int
HTL
HTL
I
int
int
170 mA for encoder supply at X3A.
U
ext
Control terminal strip (X2A) COMBIVERT with external
voltage supply 24…30 DCV/max. 1 A (dependent on vol-
tage source) for encoder supply at X3A.
15/
24 V
X3A
Voltage output for encoder supply. Voltage and
current are dependent on the adjusted source.
X3B
Voltage input 24…30 V DC, if higher HTL levels
are required.
15 V Voltage output for encoder supply. 15 V are acquired
from the internal 24 V-voltage.
I
15V
15V
150 mA for encoder supply at X3A.