Summary of COMBIVERT F5

  • Page 1

    Combivert gb instruction manual encoder interface channel 1 hiperface channel 2 variable mat.No. Rev. Dhf5zem-k002 1d.

  • Page 3

    Table of contents gb - 3 1. Safety instructions ........................................................................................ 4 1.1 validity ................................................................................................................4 1.2 qualification ...................

  • Page 4

    Gb-4 1. Safety instructions prior to performing any work on the unit the user must familiarize himself with the unit. This includes especially the knowledge and observance of the safety and warning directions. The pictographs used in this instruction manual have following meaning: danger refers to d...

  • Page 5

    Hiperface® at channel 1 gb-5 2. Product description figure 1: hiperface at channel 1 2mf5280-2028 /-2029 1mf5280-2028 /-2029 x3a channel 1 x3b channel 2 x3a channel 1 x3b channel 2 x3b x3a channel 2 channel 1 variable see material number hiperface 2.1 general each of the interface cards delivered by...

  • Page 6

    Hiperface® at channel 1 gb-6 2.4 mechanical installation all kind of works on the inverter may be carried out by authorized personnel in accordance with the emc and safety rules only. • switch inverter de-energized and await capacitor discharge time • pull off operator • remove plastic cover • remov...

  • Page 7

    Hiperface® at channel 1 gb-7 3.3 channel 1 3.3.1 specifications x3a socket sub-d15 interface type hiperface® parameter channel eia rs485 half duplex process data channel 1 vss typical (0,6…1,2v) limiting frequency 200 khz increments per revolution 1…2048 ink input resistance 120Ω 3.3.2 description o...

  • Page 8

    Hiperface® at channel 1 gb-8 3.3.3 input signals channel 1 3.3.3.1 process data channel figure 3.3.3.1 signal form a and b respectively to differential operation 360°mechanical increments per revolution a+ a- 0 0 2,5v 1vss b+ b- 2,5v 1vss 3.3.3.2 description of encoder signals during start-up an inq...

  • Page 9

    Hiperface® at channel 1 gb-9 3.3.4 connection of the encoder 3.3.4.1 encoder cabel at sub-d15 •encodercabledouble-shieldedandtwistedinpairs •connectexteriorshieldingatbothendstope/gnd •connectinteriorshieldingsatonesidetocom •don´tinterconnectexteriorandinteriorshielding figure 3.3.4.1 connection of...

  • Page 10

    Hiperface® at channel 1 gb-10 3.3.6 encoder line length the maximum line length of the encoder cable is 50 m. In addition the maximum line length of the connection line is limited by the signal frequency, cable capacity and the line resi- stance. Encoder line length = u - u min –––––––––– i max •2•r...

  • Page 11

    Hiperface® at channel 1 gb-11 4.1 hiperface® - parameter the following parameters are stored in the hiperface®-encoder and automatically read in or manually read/write by ec.38: synchronous motors: dr.23…dr.28, dr.30…32 asynchronous motors: dr.0…dr.7 encoder parameter: ec.1…3, in.31…32 controller pa...

  • Page 12

    Hiperface® at channel 1 gb-12 value description the following status messages triggers „error encoder 1“ (e.Enc1), if encoder data is read: 97 keb-referenceisundefined.Memorystructureoftheencoderdoesnotcorre- spondtothekeb-definitionandthereforedatacannotberead.Theencoderis definedbywritingdata.Atf5...

  • Page 13

    Notices gb-13.

  • Page 14

    Notices gb-14.

  • Page 15

    Notices gb-15.

  • Page 16

    Keb antriebstechnik austria gmbh ritzstraße8• a-4614 marchtrenk fon:+43724353586-0•fax:+43724353586-21 net: www.Keb.At •mail: info@keb.At keb antriebstechnik herenveld2• b-9500 geraadsbergen fon:+3254437860•fax:+3254437898 mail: vb.Belgien@keb.De keb power transmission technology (shanghai) co.,ltd....