KEB COMBIVERT F5 Instruction Manual - page 9
9
Product Description
If the encoder has 1Vpp signals, the encoder must support 2048 increments per revolution .
The numbers of increments must be set on 2048 in Parameter Ec.01.
If 1Vpp signals are detected during initialization, they are also tested for encoder breakage.
If none signals are detected, non signals are checked.
If no position value can be read from the encoder for the actual control cycle (e.g. due to er-
rors) a position value is interpolated from the two previous position values. If no position value
can be read for three times successively, the encoder interface sends the error message
Ec.37 = 68, which causes error ru.00 = E.EnCC = 35.
If the encoder supports this, data storage/-reading in/from the encoder is possible at nOP
of the control card with Ec.38 = 1/2. The data structure in the encoder is compatible with all
other F5-encoder cards.
If an error is sent directly by the encoder, the highest bit of the error value is set and sent to
the control card as status. Values > 128 are error messages directly from the encoder.
2.3
Material number
xM F5 K8G X X X X
Term of deliv-
ery
0 installed
Z Option, spare part
Interface
X3B
9 none
9019
F5 Series
suitable for
1M D, E (circuit board 1MF5280-xxxx see above)