Oki CX 1145 MFP Quick Installation - page 6
6/
*58
ADJUST
INSTALL
ADJUST
*59
-1
*61
The unit is
equipped with the auto setup function. Do
not turn the power OFF until the adjustment
for steps *58 to *61 “Automatic Gamma
Adjustment for Printer PCL 600 dpi” is
completed.
Initial Adjustment of the Auto-toner
. Turn the power switch ON.
2.Whenthecopierstartsoperating,the
message“WAIT”appears.
Installing toner cartridge
(STEP 59-2 to 59-13)
Whenpressingthe[HELP]button,theguidance
appears.
. Install cartridges Y, M and C. For the installing
procedures, see steps 59-2 to 59-6.
Closethefrontcoverafterinstallinga
cartridge and proceed to the next color by
pressing the button.
2. Install the black cartridge after installing all
color cartridges. For the installing procedures,
see steps 59-7 to 59-3.
3.Pressthe[FINISH]button.
The following adjustment should be performed
according to the order to be completed correctly.
If “Readjust from IQC-Adjustment.” or “Readjust
from Gamma-Adjustment (*).” appears on the
right side of the message “Adjustment step is not
correct.”, perform the adjustment again based
on the message.
Note: (*)
(): Automatic Gamma Adjustment for Copy
(2): Automatic Gamma Adjustment for Printer
PS3 600 dpi
(3): Automatic Gamma Adjustment for Printer
PCL 600 dpi
Image Quality Control Adjustment
1.[396]→[START]
Automatic Gamma Adjustment for
Printer PS3 600 dpi
. Select the cassette of A4 (or LT) sized paper.
(If there is no A4 (or LT) sized paper in any
cassette, be sure to set it.)
2.[47]→[FAX]
The test chart for the adjustment is output.
3.Whenadjustmenthasbeenperformed,the
following message appears in a few minutes.
Upper:Currentsensorvoltage(V)
Middle:Adjustmentvalue,Humidity(%)
Lower:Referencevoltageforadjustment(V)
Thecurrentvoltage(V)automaticallychanges
to come close gradually to the reference
voltagefortheadjustment.
(IntheorderofK>C>M>Y)
WAIT
4.Thechangeofthecurrentvoltagehasbeen
stabilizedtheauto-toneroutputvalue(bit
value)isdisplayedinMiddle,inafewminutes.
(IntheorderofK>C>M>Y)
Y: *****V M: *****V C: *****V K: 2.5V
Y: ***** M: ***** C: ***** K: ***** 39%
Y: *****V M: *****V C: *****V K: 2.5V
5.Pressthe[ENTER]button,thenthe
adjustment result is memorized and the
display returns to the initial screen.
Y: 1.25V M: 1.25V C: 1.25V K: 2.5V
Y: 73
M: 73
C: 75
K: 117
Y: 1.25V M: 1.25V C: 1.25V K: 2.5V
Note:
Theequipmentactivatesinthesetupmode
automatically when the power is turned ON
beforestep*58isfinishednormally.
LT
100%
A
TEST MODE
2.Whenthecopierstartsoperating,the
message“WAIT”appears.
LT
100%
396
TEST MODE
3. The adjustment operation will be completed in
a few minutes and there will be a return to the
initial screen.
LT
100%
396
TEST MODE
WAIT
LT
100%
A
TEST MODE
Automatic Gamma Adjustment for Copy
. Select the cassette of A4 (or LT) sized paper.
(If there is no A4 (or LT) sized paper in any
cassette, be sure to set it.)
2.[4]→[FAX]
The test chart for the adjustment is output.
3. Set the chart, facing down on the glass, in
order that the 2 black solid rectangles be
placed at the left side. Be sure to set the chart
aligned to the top left corner.
4 [1642]→[START]
The scanner automatically reads the original
and carries out the calibration of gradation.
LT
100%
4
LT
100%
1642
TEST MODE
5. If the adjustment has failed in 4, “ERROR”
appears.Theoriginalmightbedeviatingfrom
the appropriate setting position. Press the
[CANCEL]button,resettheoriginal,returnto
3 and perform the operation again.
6.Pressthe[ENTER]button.
LT
100%
1642
TEST MODE
ERROR
3. Set the chart, facing down on the glass, in
order that 2 black solid rectangles be placed
at the left side. Be sure to set the chart
aligned to the top left corner.
4.[1000]→[START]
The scanner automatically reads the original
and carries out the calibration of gradation.
LT
100%
47
5. If the adjustment has failed in 4, “ERROR”
appears.Theoriginalmightbedeviatingfrom
the appropriate setting position. Press the
[CANCEL]button,resettheoriginal,returnto
3 and perform the operation again.
LT
100%
1000
TEST MODE
6.Pressthe[ENTER]button.
Automatic Gamma Adjustment for
Printer PCL 600 dpi
. Select the cassette of A4 (or LT) sized paper.
(If there is no A4 (or LT) sized paper in any
cassette, be sure to set it.)
2.[49]→[FAX]
The test chart for the adjustment is output.
LT
100%
1000
TEST MODE
ERROR
3. Set the chart, facing down on the glass, in
order that 2 black solid rectangles be placed
at the left side. Be sure to set the chart
aligned to the top left corner.
4.[1002]→[START]
The scanner automatically reads the original
and carries out the calibration of gradation.
LT
100%
49
5. If the adjustment has failed in 4, “ERROR”
appears.Theoriginalmightbedeviatingfrom
the appropriate setting position. Press the
[CANCEL]button,resettheoriginal,returnto
3 and perform the operation again.
LT
100%
1002
TEST MODE
6.Pressthe[ENTER]button.
LT
100%
1002
TEST MODE
ERROR
7.Press[CLEAR]buttontoreturntotheinitial
screen.
LT
100%
1002
TEST MODE
Adjustment completed
Setting the Date and Time
. Turn the power switch ON.
2.Pressthe[USERFUNCTIONS]button.
3.Pressthe[ADMIN]button,pressthe
[PASSWORD]button.Keyin[123456](Initial
value)ofthe[AdminPassword]andthen
pressthe[ENTER]button.
4.Pressthe[GENERAL],the[CLOCK]andthe
[DATE/TIME]button.
5.Entervaluesfortheyear,month,date,hour
andminute,andpressthe[ENTER]button.
8.Pressandhold[ENERGYSAVER]forawhile
until the equipment is turned off.
LT
100%
A
TEST MODE