8. RF
8-1. System Hook Up and Setting
l
System Hook Up
1. Connect the Camera with the Auto EQ/RF Adjust-
ment System as shown below.
2. IC connection lip cable from the VFK1185 is not
necessary (open).
3. Set the switches on the B. E. R. counter as follows.
ERROR COUNT SW
: ON
CH SELECT SW
: AUTO
(L/R : Any one)
l
Menu Setting on Camera Recorder
1. Open the operation panel.
2. Press [SHIFT], [
®
] and [
¬
] buttons, and set the
MENU switch to the SET position.
3. Set the switches on the B. E. R. counter as follows.
PAGE
: SEVICE ADJ.
ECU CONNECT
: EVR
CONCEAL
: OFF
INNER ECC
: OFF
OUTER ECC
: OFF
SERVO MODE
: ATF
4. After the above menu setting, close the menu
mode.
l
Auto Adjustment System Normalization
(Calibration)
The system normalization (calibration) should be per-
formed when using the adjustment system at the first
time (after the completion of the system hook up) or
changing the A/D board, PC or EQ tool.
Also, we recommend to perform it regularly.
The auto adjustment system normalization procedure,
please refer to “8-10. Auto Adjustment System
Normalization (Calibration) Procedure” .
8-2. PLL VCO Adjustment
BOARD RF
SPEC.
A = B = 2.0 ± 0.1V
TEST
TP506, TP507
ADJUST EVR
MODE
PLAY
TAPE
CAMERA Colour Bar
M.EQ
Oscilloscope, EVR
EVR Setting
CMD : 02DATA : 7A ADR : 0B
1. Monitor the TP506 and 507 in the DC mode.
2. Press the [
®
] or [
¬
] button in EVR so that the
levels A and B are the same.