Panasonic AJ-D400P Service Manual - Replacement and Adjustment
10-11. S1 Post Loading Arm Unit
Replacement and Adjustment
(Removal)
1. Remove the Cassette Cover and Left Side Panel.
2. Remove the Cassette up Unit.
3. Remove the S5 Post Base Unit (Refer to item 10-
14).
4. Remove the Tension Arm Unit (Refer to item 10-
15).
5. Unscrew
the
screw (A) and remove the S1 Post
from Loading Rail as shown in Figure 10-10-1.
6. Remove the E-Ring (A) and remove the S1
Loading Arm Unit as shown in Figure 10-10-1.
(Installation)
1. Install the new S1 Loading Arm Unit according to
the opposite procedures to removing. Then S1
Post Loading Arm Unit Phase Adjustment should
be performed as shown below.
2. Adjust S1 Post Loading Arm Unit so that the hole
(A) should match hole (B) as shown in Figure 10-
10-1
3. After installing, confirm that the S1 Post moves
smoothly on the Loading Rail.
4. Tension Arm Offset (Refer to item 1-7 of section
3), Post Height Pre-Adjustment (Refer to item 1-4
of section 3) and Linearity Adjustment (Refer to
item 1-13 of section 3 [ Tape Path Adjustment
performed.
Fig. 10-10-1 Removal of S1 Post Loading Arm Unit
E-RING (A)