Panasonic AJ-D400P Service Manual - 10-14. S5 Post Base Unit
10-13-2.
Cleaner Roller Position
Adjustment
v
Required Tools
:
Eccentric Driver (VFK0357)
1. Observe the clearance (A) between Cleaner
Roller and Cylinder Unit as shown in Figure 10-
13-3. And make sure that it is within 1.0 to 1.2mm.
2. If not, loosen the 2 screws (B) and adjust the
position of Cleaner Base Plate by moving to arrow
direction (A
Û
A) with the Eccentric Driver so that
the clearance (A) is within specification. And
tighten the 2 screws (B).
Fig. 10-13-4 Cleaner Roller Position Adjustment
10-14. S5 Post Base Unit
Replacement
(Removal)
1. Remove the Cassette Up Unit
2. Unscrew
the
screw (A) and remove the S5 Post
Base Unit as shown in Figure 10-14-1.
(Installation)
1. Install the S5 post Base Unit according to the
opposite procedures to removing.
2. After installing, Post Height Pre-adjustment (Refer
to item 1-4 of section 3) and Linearity Adjustment
(Refer to item 1-13 of section 3 [ Tape Path
Adjustment Procedure ]) should be performed.
Fig. 10-14-1 Removal of S5 Post Base Unit