Panasonic AJ-D400P Service Manual - 11. Power
11. Power
11-1. D3.0V Adjustment
B O AR D P o w e r , V I D EO M A I N
SP EC .
3.15V+0.05V/-0.00V
T EST
TP9[3.15],TP6[A-GND]
(VIDEO MAIN Board)
AD J U ST VR1005(POWER Board)
I N P U T
C AM ER A C o l o u r Ba r
M O D E
R EC
M . EQ
Digital Volt Meter
1. Connect a D.V.M. to TP9,and its ground to TP6
on the VIDEO MAIN Board, then adjust VR1005
(POWER Board) so that the voltage is in the
specification.
11-2. D5.0V Adjustment
B O AR D Po w e r
SP EC .
5 . 0 0 V+/-0.10V
T EST
TP1010,TG1002[GND]
AD J U ST VR1006
I N P U T
C AM ER A C o l o u r Ba r
M O D E
R EC
M . EQ
Digital Volt Meter
1. Connect a D.V.M. to TP1010,and its ground to
TG1002 on the POWER Board, then adjust
VR1006 (POWER Board) so that the voltage is in
the specification.
11-3. A5.6V Adjustment
B O AR D Po w e r
SP EC .
5 . 6 0 V+/-0.10V
T EST
TP1008,TG1002[GND]
AD J U ST VR1004
I N P U T
C AM ER A C o l o u r Ba r
M O D E
R EC
M . EQ
Digital Volt Meter
1. Connect a D.V.M. to TP1008,and its ground to
TG1002 on the POWER Board, then adjust
VR1004 (POWER Board) so that the voltage is in
the specification.
11-4. A9.0V Adjustment
B O AR D Po w e r
SP EC .
9 . 0 0 V+/-0.10V
T EST
TP1007,TG1002[GND]
AD J U ST VR1003
I N P U T
C AM ER A C o l o u r Ba r
M O D E
R EC
M . EQ
Digital Volt Meter
1. Connect a D.V.M. to TP1007,and its ground to
TG1002 on the POWER Board, then adjust
VR1003 (POWER Board) so that the voltage is in
the specification.
11-5. A–5.6V Adjustment
B O AR D Po w e r
SP EC .
- 5 . 6 0 V+/-0.10V
T EST
TP1003,TG1002[GND]
AD J U ST VR1001
I N P U T
C AM ER A C o l o u r Ba r
M O D E
R EC
M . EQ
Digital Volt Meter
1. Connect a D.V.M. to TP1003,and its ground to
TG1002 on the POWER Board, then adjust
VR1001 (POWER Board) so that the voltage is in
the specification.
11-6. A3.6V Adjustment
B O AR D Po w e r
SP EC .
3 . 6 0 V+/-0.10V
T EST
TP1011,TG1002[GND]
AD J U ST VR1002
I N P U T
C AM ER A C o l o u r Ba r
M O D E
R EC
M . EQ
Digital Volt Meter
1. Connect a D.V.M. to TP1011,and its ground to
TG1002 on the POWER Board, then adjust
VR1002 (POWER Board) so that the voltage is in
the specification.