Panasonic AJ-D400P Service Manual - E.V.R. Direct Functions
E.V.R. Direct Functions
1.
Select in MAIN
MENU, and next selection appears.
2.
Select , and
COMMAND INPUT FUNCTION menu is available
as shown above.
3.
Input COMMAND, DATA and ADDRESS
according to adjustment procedure.
4.
After adjustment, press [ESC] key to quit.
Note:
1. After operating EVR, turn the VTR off and
on.
2. When the SYSCON PROM is updated,
execute the CAMERA RESET No.1 in
COMMAND INPUT FUNCTION menu.
Press the [F1] and [A] keys together, and
then press [ENTER] key.
3. The difference between CAMERA
RESET No.1 and No.2;
No.1 :
Adjustment data isn’t reset.
SETUP menu is reset.
No.2 :
Adjustment data is also reset.
Start Adjustment
1.
Select in MAIN
MENU.
2.
After selecting NTSC/PAL, press ENTER or ESC
key to continue.
3.
Adjustment items appear with command, data and
address;
CMD DATA
ADR
AREA
[02] [00]
[04]
[00][FF]
CMD :
Command.
DATA :
Initial data. It is not factory data. It is not VTR
data.
ADR :
Address. Confirm the Service Manual that
selected item is correct.
AREA :
Adjustable range.
4.
Select an adjustment item.
5.
Following values are displayed;
Command
= [02]
Data
= [00]
Address
= [04]
Read
Data
= [06]
Data
:
data to be sent to VTR.
Read Data
:
data sent from VTR.
6.
To adjust VTR;
1.Input data and press [ENTER] key.
2.Press [+] or [-] key.
7.
After adjustment, press [ENTER] key to quit.
Note:
1. After operating EVR, turn the VTR off and
on.
2. START ADJUSTMENT menu is possible
to read out data from VTR.
[
↑
] : Move To Up
[
↓
] : Move To Down
[
→
] : Data Increment [
←
] : Data Decrement
[ESC] : Quit
[Enter] : RAM Write
COMMAND
:
[00]
DATA
:
00
ADDRESS
:
00
[[ ]]
[ EVR FUNCTION ]
1.
CAMERA RESET No. 1
[F1],[A]
2.
CAMERA RESET No. 2
[F1],[B]
3.
VF OUT
[F1],[C]
4.
MONITOR OUT LEVEL
[F2],[0]
>
[ MACRO FUNCTION ]
1. COMMAND INPUT FUNCTION